Lynxspring, based in Lee's Summit, Missouri, builds JENEsys Edge controllers that put a full Niagara 4 station on Lynxspring's Onyxx hardware, right at the equipment. The controller on an air handler is engineered in the same Niagara Workbench, with the same wiresheet logic, Fox connection, and BACnet and Modbus drivers, as the supervisor above it. The family scales by I/O and licensing: the Edge 414 and 514 with 14 built-in I/O, the 434 and 534 with 34, the newer Edge 634 licensed for network-area management, and an Edge VAV with Guideline 36 sequences. The 514, 534, and 634 expand with Onyxx XM I/O modules, and the PC-9000 serves as Lynxspring's JACE-class Niagara 4 controller. For a Niagara-first contractor like Vertex, it's a natural fit: one toolset, one programming standard, and controllers any certified Niagara integrator can maintain.
WHAT WE DO ON LYNXSPRING
New JENEsys Edge installs
Panel design and build, controller and Onyxx I/O sizing, installation, and wiring for new equipment or controls retrofits. We match the Edge model and license to the points list instead of over-buying.
Niagara 4 programming at the controller
Sequences written in Niagara wiresheets to the same standard as our supervisor work: consistent point naming, reusable logic, and a documented sequence of operations.
Integration into your front end
Edge controllers joined to a Niagara supervisor over Fox, or to a third-party BAS over BACnet, with alarms, trends, and graphics set up end to end.
Service, backups, and upgrades
Troubleshooting, Niagara version upgrades, license changes, and station backups for JENEsys controllers we installed or inherited.
LYNXSPRING PRODUCT LINES WE WORK WITH
- JENEsys Edge 414 and 434Niagara 4 controllers for smaller equipment and price-sensitive projects, with 14 and 34 built-in I/O.
- JENEsys Edge 514 and 534Fully programmable Niagara 4 controllers with 14 and 34 built-in I/O, expandable with Onyxx XM I/O up to 306 points.
- JENEsys Edge 634Lynxspring's newest Edge controller, with 34 I/O and licensing up to 5,000 points and 100 devices for network-area management.
- JENEsys Edge VAVVAV controller with a built-in differential pressure transducer and ASHRAE Guideline 36 sequences.
- JENEsys PC-9000 and N4 SupervisorLynxspring's JACE-class Niagara 4 controller and its Niagara 4 supervisor software.
- Onyxx XM I/O14- and 34-point I/O extenders, including a BACnet MS/TP version, that add points without adding another controller.
TYPICAL PROJECTS
Edge controllers mounted at the unit, programmed for Guideline 36-style sequences, and joined to the building's Niagara supervisor.
Chiller, boiler, and pump sequencing on an Edge 534 or 634 with Onyxx XM I/O expansion, trended and alarmed at the supervisor.
JENEsys Edge VAV controllers running Guideline 36 zone sequences, programmed in the same Workbench as the rest of the building.
Standardized Niagara programs built once and reused on every unit of the same type across a portfolio.
FAQ
Lynxspring questions we hear
What is a JENEsys Edge controller?
Which JENEsys Edge model do we need?
Can JENEsys Edge controllers join our existing Niagara system?
Do you install Lynxspring controllers on retrofits as well as new construction?
Do you work on Lynxspring systems outside Louisiana?