HVAC Controls Contractor | Louisiana & Nationwide

Your building systems should work together.
We make that happen.

Controls installation, Niagara N4 programming, BACnet integration, energy management, commissioning, and mechanical HVAC service, all from one team that understands the entire system.

200+
Projects completed
15+
Years in controls
24/7
Emergency response
20-40%
Avg. energy savings
What We Do

Commercial HVAC controls and building automation services.

Every service backed by technicians who understand both the controls logic and the mechanical system it governs.

HVAC Controls Installation

DDC design, installation, and programming for air handlers, chillers, boilers, cooling towers, and VAV terminal units. Every system commissioned point-by-point.

DDCVAVChiller Controls

Building Automation Systems

Enterprise BAS on Niagara N4 with support for 200+ protocols and drivers. One dashboard for your entire facility. No vendor lock-in.

Niagara N4BACnetBAS

Energy Management

Real-time submetering, demand response, optimized scheduling, and analytics. Most clients see 20-40% HVAC energy reduction in year one.

SubmeteringAnalyticsDemand Response

Controls Engineering & Submittals

Control drawings, sequences of operation, points lists, and construction submittals. ASHRAE Guideline 36 compliant documentation.

SOOSubmittalsASHRAE 36

Commissioning & Startup

Systematic verification of every point: sensor calibration, actuator stroke, sequence execution, alarm routing, schedules, and trending.

Point VerificationCxOwner Training

Service, Maintenance & Retrofits

PM contracts, 24/7 emergency diagnostics, and legacy-to-DDC retrofits. We modernize pneumatic systems incrementally using protocol gateways.

PM Contracts24/7Retrofits

Mechanical HVAC Service

Light commercial service for RTUs, split systems, and mini-splits. Our controls + mechanical expertise means faster root-cause diagnosis.

RTUsSplit SystemsMini-Splits

Remote Niagara N4 Services

Nationwide remote BAS programming, graphics development, troubleshooting, and support via secure VPN. No travel cost, same quality.

RemoteNationwideGraphics Dev
Integration

Niagara N4 connects virtually any building system.

With 200+ drivers available through Tridium and the Niagara Community, we integrate equipment from any manufacturer, legacy or current, into a single supervisory platform.

THE BOTTOM LINE

If your building has it, Niagara can talk to it. We handle the integration so you get one login, one dashboard, one point of contact.

OPEN PROTOCOLS

BACnet IPBACnet MS/TPModbus TCPModbus RTULON/IPLonWorks FTT-10KNX/EIBMQTTOPC DA/UASNMPoBIX

PROPRIETARY SYSTEMS

Johnson N2Carrier CCNAutomated Logic WebCTRLHoneywell SpyderSchneider TACTrend IQAndover ContinuumSiemensBarber-ColmanTrane CommLink

SPECIALTY & IOT

DALI LightingEnOcean WirelessLoRaWANClipsal C-BusAllen Bradley CIPBeckhoff ADSCarel RefrigerationDanfossDynalite DyNetAmazon Echo
CONTROLS INSTALLATION

HVAC Controls Installation & DDC Programming

THE PROBLEM

Poorly programmed controls waste energy, create comfort complaints, and generate nuisance alarms. Most issues trace back to contractors who treat controls as an afterthought.

HOW WE SOLVE IT

We're a controls-first contractor. Every technician understands both the DDC logic and the mechanical equipment it governs, so we catch problems at the source and commission systems that actually perform to spec.

DDC controller installation and wiring for AHUs, VAV boxes, chillers, boilers, and cooling towers
Custom sequence of operations programmed to your building's operational requirements
Sensor calibration, actuator stroke verification, and full point-by-point checkout
Multi-vendor controller integration: Tridium JACE, Honeywell, JCI, Schneider, iSMA, Reliable Controls, Carrier i-Vu
BUILDING AUTOMATION

Building Automation Systems & Niagara N4 Programming

THE PROBLEM

Siloed systems from different vendors that can't communicate. No single view of your building. Vendor lock-in that makes every change expensive.

HOW WE SOLVE IT

We engineer enterprise BAS on Niagara N4, the industry's most flexible open integration platform. With support for 200+ protocol drivers through Tridium and the Niagara Community, we connect BACnet, Modbus, LON, KNX, MQTT, OPC, and dozens of proprietary protocols into one unified system.

Niagara N4 station architecture, server deployment, and JACE programming
Custom HTML5 graphics: interactive floor plans, system schematics, and dashboards
Multi-protocol integration: BACnet IP/MSTP, Modbus TCP/RTU, LON, KNX, MQTT, OPC, and legacy drivers
Alarm management, trending, scheduling, historical reporting, and cloud-connected remote access
ENERGY OPTIMIZATION

Energy Management & Building Analytics

THE PROBLEM

You're paying too much to heat and cool your building, but you can't pinpoint where the waste is, and your utility bills don't give you the granularity to act.

HOW WE SOLVE IT

A properly tuned building automation system is the single most effective way to cut HVAC energy costs. We implement real-time submetering, automated demand response, and analytics dashboards that identify waste and verify savings.

Real-time electrical, gas, water, and BTU submetering with cost allocation
Optimized start/stop, supply air temperature reset, static pressure reset, and condenser water reset
Peak demand load shedding and automated demand response
Energy dashboards with consumption trends and M&V reporting for utility incentive programs
CONTROLS ENGINEERING

Controls Engineering, Drawings & Submittals

THE PROBLEM

You need controls documentation that your GC, engineer, and commissioning agent can actually use, not generic submittals cobbled together from cut sheets.

HOW WE SOLVE IT

We produce the engineering deliverables that move projects forward: control system design drawings, detailed sequences of operation, BAS points lists with naming conventions, and construction submittal packages. ASHRAE Guideline 36 compliant.

Control system design drawings and riser diagrams in AutoCAD
Sequences of operation written per piece of controlled equipment
BAS points lists with BACnet object naming and addressing conventions
Construction submittal packages with cut sheets, compliance matrices, and approval tracking
COMMISSIONING

Controls Commissioning & Owner Training

THE PROBLEM

A brand-new controls system that nobody verified. Sensors reading wrong. Sequences that don't match the spec. Alarms nobody configured. Staff that doesn't know how to use it.

HOW WE SOLVE IT

Commissioning is where controls projects succeed or fail. We systematically verify every point in your system, then train your staff to operate and maintain it with confidence.

Pre-functional checklists for every controller and field device
Point-by-point functional testing against the written sequence of operations
Integrated system testing across all trades: HVAC, lighting, fire, access
Hands-on owner training, as-built documentation, and O&M manual delivery
SERVICE & RETROFITS

Preventive Maintenance, Emergency Service & Retrofits

THE PROBLEM

Your controls system hasn't been touched since it was installed. Sensors have drifted. Software hasn't been updated. When something breaks, nobody knows how to fix it.

HOW WE SOLVE IT

We offer service contracts with scheduled inspections, software updates, sensor recalibration, and priority emergency response. For legacy systems, we modernize pneumatic-to-DDC incrementally using Niagara protocol gateways. No full rip-and-replace required.

Preventive maintenance contracts with quarterly or biannual scheduled visits
24/7 emergency remote diagnostics. Most issues resolved within 1-2 hours
Controller firmware updates, security patching, and software optimization
Legacy pneumatic-to-DDC migration planning with protocol gateway integration
MECHANICAL HVAC

Light Commercial Mechanical HVAC Service

THE PROBLEM

Is it a controls issue or a mechanical failure? Most contractors can only diagnose one side. That means multiple truck rolls, finger-pointing, and longer downtime.

HOW WE SOLVE IT

Because our technicians understand both controls and mechanical systems, we diagnose the actual root cause on the first visit. We service RTUs, split systems, mini-splits, and packaged equipment, so one call handles both sides of the problem.

Rooftop unit (RTU) maintenance, repair, and replacement for all major brands
Split system and mini-split installation, diagnostics, and service
Compressor, motor, and fan replacement with electrical diagnostics
Refrigerant charging, leak detection, recovery, and EPA-compliant handling
REMOTE / NATIONWIDE

Remote Niagara N4 Programming & BAS Support

THE PROBLEM

You need Niagara work done but there's no qualified integrator in your area. Travel costs are eating your budget. Scheduling takes weeks.

HOW WE SOLVE IT

We provide remote BAS services nationwide via secure VPN: Niagara N4 station building, custom HTML5 graphics, device integration, troubleshooting, and ongoing support. Same quality as on-site, without the travel cost or scheduling delays.

Remote Niagara N4 programming, station configuration, and network architecture
Custom HTML5 graphics development: floor plans, system schematics, dashboards
BACnet and Modbus device discovery, integration, and point mapping
Ongoing remote support contracts with guaranteed same-business-day response

Let's talk about your building.

Free estimate on any controls, automation, or mechanical service. We'll scope it, price it, and explain exactly what you're getting.