Distech Controls, based in Brossard, Québec, and part of Acuity, builds open, IP-based building controls. Its Eclypse family runs from the ECY-APEX flagship and the modular ECY-S1000 Connected System Controller for central plants and large air handlers, through the ECY-400 and ECY-600 series for equipment and plant control, down to VAV and terminal unit controllers. Eclypse controllers are BTL-listed, communicate natively over BACnet/IP with MS/TP and BACnet/SC support, and are programmed in Distech's EC-gfxProgram graphical environment. For Niagara sites, Distech also offers EC-Net, its Niagara 4-based software, and the EC-BOS-9 Niagara 4 building controller, while Resense and Allure room devices handle the occupant side. Vertex installs, programs, and services Distech systems for new construction and retrofits, and ties them into Niagara 4 or another BACnet front end.
WHAT WE DO ON DISTECH CONTROLS
New Eclypse installs
Controller selection, panel design and build, installation, and IP network design for air handlers, rooftop units, VAV, and central plants.
EC-gfxProgram programming
Sequences built in EC-gfxProgram with consistent point naming and a documented sequence of operations, ready for the next engineer to pick up.
Niagara and BACnet integration
Eclypse controllers brought into a Niagara 4 or EC-Net station over BACnet/IP, or into another BACnet front end, with graphics, trends, and alarms at the supervisor.
Service and expansion
Troubleshooting, firmware updates, and new controllers added to existing Distech systems we installed or inherited.
DISTECH CONTROLS PRODUCT LINES WE WORK WITH
- ECY-APEXDistech's flagship Eclypse controller for large, complex applications.
- ECY-S1000 Connected System ControllerModular Eclypse controller for central plants and large mechanical equipment.
- ECY-400 and ECY-600 seriesEclypse equipment controllers for air handlers, rooftop units, chillers, boilers, pumps, and cooling towers; the 450 and 650 add a built-in display.
- Eclypse VAV and terminal unit controllersECY-VAV, ECY-PTU, and ECY-TU controllers for VAV boxes and terminal units.
- EC-gfxProgramDistech's graphical programming environment for Eclypse controller logic.
- EC-Net and EC-BOS-9Distech's Niagara 4-based software and Niagara 4 building controller.
- Resense and Allure room devicesRoom sensors and displays for temperature, air quality, occupancy, and occupant setpoint control.
TYPICAL PROJECTS
Eclypse controllers programmed for the sequence and integrated into the building's front end.
Eclypse terminal unit controllers and room devices replacing failed or proprietary zone controls.
Eclypse controllers on the building's IP network, designed with the owner's IT team from the start.
Distech systems tied into a Niagara 4 front end alongside other manufacturers' equipment.
FAQ
Distech Controls questions we hear
What is Distech Controls Eclypse?
Can Distech Eclypse controllers work with Niagara?
Do you install Distech on retrofits as well as new construction?
Do you service existing Distech systems?
Do you work on Distech Controls systems outside Louisiana?
Distech Controls, Eclypse, EC-gfxProgram, EC-Net, Resense, Allure, and Niagara are trademarks of their respective owners.