iSMA CONTROLLI

iSMA CONTROLLI Controller Installation & Programming

Niagara-ready controllers and I/O from the plant room down to the VAV box. We install, program, and integrate iSMA CONTROLLI hardware.

MAC36PROnano EDGE ENGINEAAC20MIX / MINI I/ONiagara 4

iSMA CONTROLLI, based near Genoa, Italy, was formed in 2021 from valve and actuator maker Controlli and Global Control 5, the Polish company that created the iSMA brand. Its lineup covers the whole building: the MAC36PRO, a Niagara 4 controller with 36 I/O, and the iSMA-B-J9, iSMA's JACE 9000, at the supervisory level; nano EDGE ENGINE controllers such as the VAV14-IP and RAC18-IP for VAV boxes and rooms, programmable from Niagara Workbench; Sedona-based AAC20 and fan coil controllers; and MIX, MAX, and MINI I/O modules on BACnet and Modbus. Vertex installs iSMA controllers and I/O, programs them, and integrates them into Niagara 4 or another BACnet front end.

WHAT WE DO ON ISMA CONTROLLI

New iSMA installs

Controller and I/O module selection, panel design and build, installation, and wiring for air handlers, rooftop units, VAV boxes, fan coils, and plant equipment.

Niagara and controller programming

MAC36PRO and JACE logic in Niagara Workbench, nano EDGE ENGINE controllers through iSMA's Niagara tools or iC Tool, and Sedona applications on AAC20 and fan coil controllers.

Niagara and BACnet integration

iSMA controllers and I/O brought into a Niagara 4 station or another BACnet system, with graphics, trends, and alarms at the supervisor.

Expansion, replacements, and service

Added I/O and controllers on existing iSMA systems, end-of-life MAC36NL controllers replaced with the MAC36PRO, troubleshooting, and backups.

ISMA CONTROLLI PRODUCT LINES WE WORK WITH

  • MAC36PRO
    Niagara 4 master application controller with 36 I/O, replacing the end-of-life MAC36NL.
  • iSMA-B-J9
    iSMA's JACE 9000 Niagara 4 supervisory controller.
  • nano EDGE ENGINE controllers
    VAV14-IP with an integrated actuator and pressure sensor, RAC18-IP room controller, and UAC28-IP for unitary and plant equipment.
  • AAC20 and fan coil controllers
    Sedona-based advanced application and fan coil controllers on BACnet and Modbus.
  • MIX, MAX, and MINI I/O
    BACnet and Modbus I/O modules that add points to a controller or supervisor.
  • iSMA Supervisor
    Server-level Niagara platform for multi-site monitoring and analytics.

TYPICAL PROJECTS

MAC36NL replacements

End-of-life MAC36NL controllers swapped for the MAC36PRO, with Niagara stations migrated and the equipment kept running.

VAV and room control

VAV14-IP and RAC18-IP controllers on VAV boxes and in rooms, tied back to the building's Niagara supervisor.

Air handler and plant controls

MAC36PRO or UAC28-IP controllers at the equipment, programmed for the sequence and trended at the supervisor.

Remote I/O

MIX and MINI I/O modules adding points to an existing controller or supervisor without another full controller.

FAQ

iSMA CONTROLLI questions we hear

What is iSMA CONTROLLI?
An Italian building automation manufacturer formed in 2021 from Controlli and Global Control 5, the company that created the iSMA brand. It makes Niagara 4 controllers, nano EDGE ENGINE and Sedona-based controllers, I/O modules, and room panels.
Do iSMA controllers work with Niagara?
Yes. The MAC36PRO and iSMA-B-J9 run Niagara 4, nano EDGE ENGINE controllers can be programmed from Niagara Workbench, and the rest of the line integrates over BACnet and Modbus.
Our MAC36NL controllers are end-of-life. What now?
iSMA's direct replacement is the MAC36PRO. iSMA lists last-time-buy for the MAC36NL through December 2026 and Niagara 4 updates through 2028, so there is time to plan a phased swap.
When do you use iSMA I/O modules instead of another controller?
When a site needs more points but not more logic. MIX and MINI I/O modules add inputs and outputs to an existing controller or supervisor over BACnet or Modbus, which is often cheaper and simpler than adding a controller.
Do you work on iSMA CONTROLLI systems outside Louisiana?
Yes. We are on-site across Louisiana, travel nationwide for iSMA CONTROLLI installation and commissioning work, and support systems remotely in all 50 states over secure VPN.

iSMA CONTROLLI, nano EDGE ENGINE, Sedona, JACE, and Niagara are trademarks of their respective owners.

Have a iSMA CONTROLLI project?

New iSMA CONTROLLI installs, expansions, programming, and service. Tell us about the building and we'll send a clear scope and an honest price.